HEFEI ECOLITE ENERGY CO., LTD.

Let's use lithium energy technology to return the earth to a blue sky and sea.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / LiFePO4 Battery Cells /

3.2V 50Ah LiFePO4 Rechargeable Li Ion Battery For Solar System

Contact Now
HEFEI ECOLITE ENERGY CO., LTD.
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:MrMorley
Contact Now

3.2V 50Ah LiFePO4 Rechargeable Li Ion Battery For Solar System

Ask Latest Price
Video Channel
Brand Name :Ecolite
Model Number :3.2v 50Ah
Certification :UN38.3 MSDS CE
Place of Origin :China
MOQ :1000pcs
Price :Inquiry
Payment Terms :L/C, T/T
Supply Ability :5000 units/month
Delivery Time :5-8 work days
Packaging Details :Carton Pallet Container
Battery width(mm) :140.2±0.5
Battery height H1(No Pole mm) :157.2±0.5
Battery height H2(Including Pole mm) :160.0±0.5
Battery thickness T(Free state mm) :24.0±0.5
Positive plate edge to shell edgeD1 :12.3±0.5
Plate length D2 :35±0.5
Plate spacing D3 :80±0.5
Plate width D4 :15±0.5
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3.2v 50Ah LFP Rechargeable Li-Ion Battery For Solar System

1 Preface
This specification describes the type and size, performance, technical characteristics, warning and caution of the prismatic power cell. The specification only applies to IFP23140160-50Ah cell supplied by HEFEI HOYE ECOLIENG TECHNOLOGY CO., LTD

2 Definition
2.1Rated capacity:
Rated capacity=50.0Ah: The capacity obtained when a cell is discharged at 1C to
2.5 volts at 25 ± 2.5℃

2.2Standard charge method:
At 25 ± 2.5℃, charge to 3.65V at a constant current of1C, and then, charge continuously with constant voltage of 3.65V until the charge current drops below 0.05C.
2.3Standard discharge method:

At 25 ± 2.5℃, discharge to 2.5 V at a constant current of 1C.
2.4Standard discharge method:
From the date of production to the time when the capacity decreases to 80% of the initial capacity

3 Executive standard
GB/T 31467.3-2015 Lithium-ion power battery packs and systems for electric vehicles Part 3: Safety requirements and test methods
GB/T 31484-2015 Cyclic Life Requirements and Test Method of Power Batteries for Electric Vehicles
GB/T 31485-2015 SafetyRequirementsandTestMethodof PowerBatteriesforElectric Vehicles GB/T 31486-2015 Electrical Performance Requirements and Test Method of Power Batteries for Electric Vehicles

4 Cell size(Including bluefilm)

ITEM Parameter
Battery width(mm) 140.2±0.5
Battery height H1(No Pole mm) 157.2±0.5
Battery height H2(Including Pole mm) 160.0±0.5
Battery thickness T(Free state mm) 24.0±0.5
Positive plate edge to shell edgeD1 12.3±0.5
Plate length D2 35±0.5
Plate spacing D3 80±0.5
Plate width D4 15±0.5

4Cell parameters
4.1Basic parameters 1

ITEM SPECIFICATION
Rated capacity (Ah) 50.0
voltage platform(V) 3.2V
Initial capacity (Ah) ≥50
Limited voltage in charge 3.65 V
Final voltage in discharge (temp>0℃) 2.50 V
Final voltage in discharge (temp≤0℃) 2.00 V
Discharge temperature -30 ~60
Charge temperature 0 ~60

ITEM SPECIFICATION
Charging and discharging current Refer to Article 6, Charging and Discharging Strategies
ACR (25℃,100% SOC)mΩ ≤0.65
DCR (25℃,100% SOC)mΩ ≤3
Capacity retention25℃,100%SOC,30days ≥96%
Capacity retention 60℃,100%SOC,7days ≥96%
Cycle life@25℃,1C ≥2000 times
Calendar life (25℃) ≥10 year
Cell safety performance Crush/ Nail/ Over charge/ Over discharge/ Heating/ Free fall etc.
Opening pressure of explosion-proof valve 0.8±0.2Mpa
Battery weight (Kg) 1.10±0.05
Appearance No deformation or cracks, no burrs, no drying, no trauma, no dirt, clear and correct marks.
Humidity range 0 ~ 90 % RH (non-condensing )
Atmosphere 70kPa~106kPa

5.2Basic parameters 2
Different Temperature Capacity, Energy Retention Rate

5.3 SOC-OCV

temp

SOC

Discharge SOC- OCV
-20℃ -10℃ 0℃ 10℃ 25℃ 35℃ 45℃ 55℃
100 3.348 3.349 3.353 3.350 3.358 3.350 3.344 3.342
90 3.300 3.310 3.319 3.325 3.330 3.333 3.334 3.335
80 3.291 3.306 3.318 3.324 3.329 3.331 3.332 3.333
70 3.282 3.296 3.310 3.322 3.328 3.330 3.331 3.332
60 3.275 3.286 3.293 3.300 3.311 3.316 3.317 3.317
50 3.270 3.279 3.283 3.287 3.292 3.296 3.297 3.300
40 3.266 3.274 3.278 3.281 3.288 3.292 3.295 3.298
30 3.261 3.269 3.275 3.279 3.284 3.287 3.283 3.280
20 3.253 3.262 3.265 3.263 3.253 3.250 3.248 3.245
10 3.248 3.242 3.231 3.217 3.206 3.205 3.205 3.205
0 3.240 3.218 3.188 3.065 2.828 2.754 2.744 2.616

5 Charging and DischargingStrategy

Continuous Chargingcurrent

temp/SOC T≤0℃ 0<T≤5℃ 5<T≤10℃

10<T≤1

5℃

15<T≤3

5℃

35<T≤4

0℃

40<T≤4

5℃

45<T≤5

0℃

50<T≤5

5℃

55<T≤6

0℃

>60℃

100%

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

95%

0C

0.33C

0.33C

0.5C

0.5C

0.5C

0.33C

0.2C

0.1C

0C

0C

90%

0C

0.33C

0.5C

0.5C

0.5C

0.5C

0.33C

0.2C

0.1C

0C

0C

80%

0C

0.33C

0.5C

0.75C

0.75C

0.75C

0.5C

0.2C

0.1C

0C

0C

70%

0C

0.33C

0.5C

1C

1C

0.75C

0.5C

0.33C

0.2C

0C

0C

60%

0C

0.33C

0.5C

1C

1C

0.75C

0.5C

0.33C

0.2C

0C

0C

50%

0C

0.33C

0.5C

1C

1C

0.75C

0.5C

0.33C

0.2C

0C

0C

40%

0C

0.33C

0.5C

1C

1C

0.75C

0.5C

0.33C

0.2C

0C

0C

30%

0C

0.33C

0.5C

1C

1C

0.75C

0.5C

0.5C

0.2C

0C

0C

20%

0C

0.33C

0.5C

1C

1C

0.75C

0.75C

0.5C

0.5C

0C

0C

10%

0C

0.33C

0.5C

1C

1C

0.75C

0.75C

0.5C

0.5C

0C

0C

5%

0C

0.33C

0.5C

1C

1C

0.75C

0.75C

0.5C

0.5C

0C

0C

0%

0C

0.33C

0.5C

1C

1C

0.75C

0.75C

0.5C

0.5C

0C

0C

Form 6: Maximum pulse charging current IBmax(SOC,T,30s)

temp/SOC

T≤0

0<T≤5

5<T≤10

10<T≤1

5℃

15<T≤3

5℃

35<T≤4

0℃

40<T≤4

5℃

45<T≤5

0℃

50<T≤5

5℃

55<T≤6

0℃

>60℃

100%

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

95%

0C

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0C

90%

0C

0.33

0.33

0.5

0.5

0.5

0.5

0.5

0.33

0.33

0C

80%

0C

0.5C

0.75C

1C

1C

1C

1C

1C

0.75C

0.5C

0C

70%

0C

0.5C

0.75C

1C

1C

1C

1C

1C

0.75C

0.5C

0C

60%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.5C

0C

50%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.5C

0C

40%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.5C

0C

30%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.5C

0C

20%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.75C

0C

10%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.75C

0C

5%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.75C

0C

0%

0C

0.5C

0.75C

2C

2C

1C

1C

1C

0.75C

0.75C

0C

form 7:Maximum continuous discharge current I’max(SOC,T)

Tem/SOC

-30<T≤

-25

-25<T≤

-20℃

-20<T≤

-10℃

-10<T

≤0℃

0<T≤

5℃

5<T≤

10℃

10<T≤

15℃

15<T≤

35℃

35<T

≤40℃

40<T⩽

45℃

45<T

⩽ 50℃

50<T

⩽55℃

55<T

⩽60℃

>60℃
100% 0.33C 0.5C 0.5C 0.5C 1C 1C 1C 1C 1C 1C 0.75C 0.5C 0.33C 0C
95% 0.33C 0.5C 0.5C 0.5C 1C 1C 1C 1C 1C 1C 0.75C 0.5C 0.33C 0C

90%

0.33C

0.5C

0.5C

0.5C

1C

1C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

80%

0.33

C

0.5C

0.5C

0.5C

1C

1C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

70%

0.33

C

0.5C

0.5C

0.5C

1C

1C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

60%

0.33

C

0.33C

0.33C

0.5C

0.75C

1C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

50%

0.33

C

0.33C

0.33C

0.5C

0.75C

1C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

40%

0.33

C

0.33C

0.33C

0.5C

0.75C

0.75C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

30%

0.33

C

0.33C

0.33C

0.5C

0.75C

0.75C

1C

1C

1C

1C

0.75C

0.5C

0.33C

0C

20%

0.1C

0.33C

0.33C

0.5C

0.75C

0.75C

0.75C

0.75C

0.75C

0.75C

0.5C

0.33C

0.33C

0C

15%

0.1C

0.1C

0.33C

0.33C

0.5C

0.5C

0.5C

0.5C

0.5C

0.5C

0.5C

0.33C

0.2C

0C

10%

0C

0C

0.33C

0.33C

0.33C

0.33C

0.33C

0.33C

0.33C

0.33C

0.33C

0.2C

0.2C

0C

5%

0C

0C

0.1C

0.15C

0.2C

0.2C

0.2C

0.2C

0.2C

0.2C

0.2C

0.2C

0.2C

0C

0%

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

form 8:Maximum Pulse Discharge

Temp/SOC

-30<T

≤-25

-25<T

≤-20

-20<T

≤-10

-10<

T≤0

0<T≤

5℃

5<T≤

10℃

10<T

≤15

15<T

≤35

35<T

≤40

40<T

45

45<T

50

50<T

55

55<T

60

>60

100%

0.5C

0.5C

0.5C

0.75C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

95%

0.5C

0.5C

0.5C

0.75C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

90%

0.5C

0.5C

0.5C

0.75C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

80%

0.5C

0.5C

0.5C

0.75C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

70%

0.5C

0.5C

0.5C

0.75C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

60%

0.33C

0.33C

0.33C

0.5C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

50%

0.33C

0.33C

0.33C

0.5C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

40%

0.33C

0.33C

0.33C

0.5C

1C

1C

2C

2C

2C

2C

1.5C

0.75C

0.33C

0C

30%

0.33C

0.33C

0.33C

0.5C

1C

1C

2C

2C

2C

2C

1.5C

0.5C

0.33C

0C

20%

0.1C

0.33C

0.33C

0.5C

0.75C

0.75C

0.75C

1C

1C

1C

0.75C

0.5C

0.33C

0C

15%

0.1C

0.1C

0.33C

0.33C

0.5C

0.5C

0.75C

0.75C

0.75C

0.75C

0.75C

0.33C

0.2C

0C

10%

0C

0C

0.33C

0.33C

0.33C

0.33C

0.5C

0.5C

0.5C

0.5C

0.5C

0.33C

0.2C

0C

5%

0C

0C

0.1C

0.15C

0.2C

0.2C

0.33C

0.33C

0.33C

0.33C

0.33C

0.33C

0.2C

0C

0%

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

0C

Current I’max(SOC,T,30s)

6 Packagepicture

7 Storage and qualitywarranty
7.1For different storage environment,pls check followingform

Temperature Storage time SOC capacity rentation
-20~35℃ ≤6 months 30%≤SOC≤60%
35~45℃ ≤3months 30%≤SOC≤60%

7.2 25storage:

Storage time 30days storage 60days storage 90days storage 180days storage
Voltage drop standard/mV ≤5 ≤8 ≤10 ≤20

Shelf life: calendar life of 10 years or cycle life of 2000 times (based on first come) Regular maintenance
For storage cores that have been used for more than 6 months, the starting time is the delivery time of our cores; if regular maintenance is required, 0.5C current constant charging should be carried out to 3.6V, 3.6V constant voltage to 0.05C, 0.5C constant current discharging to 2.5V after 10 minutes, 0.5C constant current charging to 3.2V after 10 minutes, 3.2V constant voltage charging to 0.05C, and the process ends. If abnormal cores are found in the maintenance process, we should contact our company to deal with them in time

9.Warning and cautions in handling the lithium-ion cell
To prevent the possibility of the cell from leaking, heating, explosion, please observe the following precautions:
Don’t immerse the cell in water.
Don’t use and leave the cell near a heat source, such as fire or heater. Don’t discard the cell in fire or heater.
Don’t connect the positive and negative terminal directly with metal objects.
Don’t transport and store the cell together with metal objects such as necklaces, hairpins. strike, throw or trample the cell.
Don’t directly solder the cell.
Don’t pierce the cell with a nail or other sharp object.

Caution

If the cell leaks and the electrolyte get into your eyes, don’t wipe eyes, instead, thoroughly rinse the eyes with clean running water for at least 15 minutes, and immediately seek medical attention. Otherwise, eye injury can result. If the cell gives off an odor, generates heat, becomes discolored or deformed, or in any way appears abnormal during usage, recharging or storage, immediately remove it from the device or cell charger and stop using it.

Fill out our short form and we will be contacting you shortly to see we how can provide a solution to your needs!

Inquiry Cart 0